Quantity | 3+ units | 10+ units | 30+ units | 50+ units | More |
---|---|---|---|---|---|
Price /Unit | $248.37 | $243.30 | $235.70 | $225.56 | Contact US |
800ml/min PEM Electrolyzer for Hydrogen Oxygen Hydrogen Generator Hydrogen Rich Water Generator
Features:
- Series A electrolyzer
- 26A rated current
- Small and sophisticated
- Stable gas production performance
Package Included:
- 1 x Electrolyzer
Attention:
-
Please operate this device strictly according to the instructions for
use. If you have any questions, please consult customer service.
Warranty and Disclaimer:
Under
normal use conditions, the warranty period of the product is 1 year,
starting from the time the electrolyzer leaves the factory.
The following conditions are not covered by the warranty:
1. Causes of circuits and control systems themselves, failure of other electronic components, etc.
2. Substandard water quality (e.g. mineral water, tap water or other liquids is used).
3. Ion exchange resin is not used.
4.
Operating the equipment in the event of water shortage (including dry
burning caused by the return of oxygen from the water inlet due to
unreasonable system design).
5. The power supply of the electrolyzer
is unstable and mismatched (for example, the current fluctuation
amplitude of the power supply is large: the fluctuation amplitude of the
current under actual working conditions is large, far exceeding the
rated current, and the electrolyzer will be seriously damaged).
6. The electrolyzer is connected to the positive and negative poles of the power supply reversely, resulting in burning.
7. Artificial disassembly and reassembly and its performance cannot be restored.
8. Other man-made and accidental damage or sabotage.
Instructions for use:
I. Product Design:
1.
Hydrogen products should be designed with a constant current power
supply that matches the voltage and current parameters of the
electrolyzer, otherwise they will cause damage to the electrolyzer or
the performance is not up to standard;
2. When the product is
designed, the height difference between the outlet of water tank and the
inlet of the electrolyzer should be greater than 10cm/3.9"; Or equipped
with a circulating water pump. When setting the circulating water pump,
there is no requirement for the height difference between the outlet of
the water tank and the inlet of the electrolyzer;
3. The operating
efficiency of the electrolyzer has a high correlation with the working
temperature. Frequent low temperature start-up will cause certain damage
to the electrolyzer, so the starting temperature should be fully
considered in the product design. Solving this problem requires
optimization in product design. On the one hand, the supply current
output at power supply start-up is controlled by a built-in program. The
output current gradually rises and finally stabilizes at the rated
operating current (the parameters should be consistent with the relevant
model). During this period, the working voltage does not exceed the
rated voltage; On the other hand, an automatic instantaneous heating
module or water tank heating module should be set between the outlet of
the water tank and the inlet of the electrolyzer to ensure that the
water temperature flowing into the electrolyzer is not less than 25°C;
4.
In order to ensure the long-term stable operation of the electrolyzer,
it is recommended to equip the product with an ion exchange resin
filtration device when designing. It can be set between the outlet of
the water tank and the inlet of the electrolyzer to ensure that the
electrolyzed water meets the use standard;
5. If the electrolyzer
reuses the circulating water from the oxygen port, it is recommended to
use the circulating water after ion exchange resin treatment
(conductivity< 5uS/cm). It is recommended to add an ion exchange
resin filter;
6. The internal space should be reasonably designed
when designing the product, especially there is enough space around the
electrolyzer, and the appropriate flow channel design should designed to
ensure normal air flow to achieve a good heat dissipation effect;
7.
The size of the water tank should correspond to the technical data
table. Level control and alarm devices should be set in the water tank
to ensure that the water storage is above the minimum liquid level
(refer to the technical data table for specific values).
II. Product Assembly Process:
1.
In the process of product assembly, it is necessary to fully understand
the working principle and characteristics of the electrolyzer, prevent
the joints and nozzles of the electrolyzer from being contaminated by
other substances, and keep your assembly workshop clean;
2. When
connecting the circuit system, carefully distinguish the positive and
negative electrodes of the electrolyzer to prevent reverse connection,
because reverse connection will cause the electrolyzer to be burned;
3.
Pipeline connection should be stable and reliable, with suitable
temperature resistance, pressure resistance and hydrolysis resistance to
prevent leakage caused by aging or falling off; Materials that come
into contact with water must be resistant to corrosion, oxidation and
high temperatures. Users who must use metal materials are recommended to
use pure titanium.
4. Electrical components should be strictly
selected to ensure safety. Adopt a reasonable connection process to
reduce unnecessary overheating. The quality of the connection wire
between the power supply and the electrolyzer should be ensured. The
connection end must be tightened in a reliable way, otherwise a large
amount of heat will be generated, resulting in potential safety hazards.
III. Conditions of Use and Common Sense:
-
Customers should write accurate and comprehensive product manuals to
ensure that users can use the products correctly and reasonably in
accordance with the instructions;
- Purified/deionized/secondary
distilled water (conductivity <5uS/cm) must be used and C'estbon
purified water is recommended;
- Customers must be reminded to pay
attention to the water level, and it is strictly forbidden to operate
with water shortage to prevent the electrolyzer from burning.
- A PEM
electrolyzer is a device that requires specific conditions to function
properly. Reasonable design, matching, process and use can greatly
extend the service life of the device. High-quality hydrogen products