• Elevator Door Controller Inverter Lift Accessories Panasonic Inverter 0.4kw Door Elevator Parts AAD03011DK AAD0302

Elevator Door Controller Inverter Lift Accessories Panasonic Inverter 0.4kw Door Elevator Parts AAD03011DK AAD0302

Availability: In stock, usually dispatched in 1 business day

  • Price:$229.76
  • Price in reward points: 2298 Reward Points: 23
  • Quantity 3+ units 10+ units 30+ units 50+ units More
    Price /Unit $225.16 $220.57 $213.68 $204.49 Contact US
Quantity:

Elevator Door Controller Inverter Lift Accessories Panasonic Inverter 0.4kw Door Elevator Parts AAD03011DK AAD0302

Description:
- Single-phase200VInput type
- Applicable motor output: 0.4kw
- Rated output current: 2.8A
- Rated output capacity: 1.1kVA
- Power capacity: 1.3kVA
- Estimated weight: 1.2kg
1. End model D: No brake type .
2. Rated output capacity of the output voltage230V ACWhen the value of .
3. Due to the impedance of the power supply side of the power supply capacity varies .
- Available functions of the drive motor (AC) , Three-phase multi- speed control
- The encoder input can detect the location and multi-speed control
- You can also follow the input sensor multi-speed operation , ( encoder input terminal switching )
- Door amplitude measurement function
- WithRS485CommunicateI / F( Through a dedicated protocol , you can complete a variety of settings , monitoring, operation display )
- Equipment dedicated input terminals
Relay output3Point withSet basic parameters ( design parameters :P76~P79)

No open door/Closed arrival signal
- Parameter name Setting range Unit Default Operation Could ChangeP76Whether the open/Closed selection signals arriving0-2 % 0Can notP77Slip arrival judging frequency0.1-10.0HZ1.0You can changeP78Slip arrival time determination1-999MS100P79Slip into the open to reach the generation of choice0( NotReset)0.1-10.0SEC0
- P76 Opening and closing arrival signal arriving signal arrival signals simultaneously openONNo abnormal opening and closing arrival signal arriving signal abnormality No abnormality0There isSWThere isSWThe detection may be detected may be detected possible1No ( judging by the rotation frequency ) haveSWDetection may not be detected in the detection possible2No ( judging by the rotation frequency ) without ( judging by the rotation frequency ) detection may not be detected without detection specification selection
- SWThe way (P09 = 4,5), The open/Closed arrival signal must have ,P76Setting invalid
- Determining setting accuracy
- The encoder according to the detection signal from the calculated frequency difference confirmed place by determining the slide door switch .
- P77( Slip arrival judging frequency ) powerONWhen , in order toDOORNo malfunction when measured amplitude , please set the value becomes smaller.
- Determined that the set time
- When you start to prevent open/Malfunction cut off for the time , placeP78( Slip arrival determination time ) set larger.
- With respect toDOORPosition dataRESET
- According slip arrives judgment arrives,DOORData location is notreset( In arriving signal (SW)RESET)
- Want the position data of the RESET DOOR , in the P79( Slip open arrive substituting selection) set time )
- Change the set position on arrival
- No arrival signal specifications of doors,DOORThe movable range= DOORThe magnitude of the measured values
- In normal operation , it will happenDOORLocation data is not becoming to reach areas, to really become reach areas
- Can change the opening ( and closing ) reaches the set position (D02,D08) .
- Closed arriveD02Rise ( example : set5%Then ,5% -0 % = 5%Become reach the magnitude of the field )
- Open arrivalD08Decline ( for example: set95%Then ,100% -95 % = 5%Become reach the magnitude of the field )
- P76 = 2(No open/Necessary OFF signal )
- Power supplyONWhen ,DOORSandwiched measured magnitude occurred , then because of the position as close to the position of judge ,
- Unable to carry out normalDOORControl . It is necessary to set the sandwich detected slip ratio can be detected much earlier

Specifications:
- Standard applicable motor output: 0.4 kW
- Rated output voltage: 3Phase 200 ~ 230V AC ( mains voltage proportional )
- Overload current rating: 150% of rated output current for 1 minute
- Phase/Voltage/Frequency: Single-phase/200~ 230V AC50 / 60Hz
- Allowable voltage fluctuation: Rated input AC voltage of +10 % - 15%
- Permissible frequency fluctuation: Rated input frequency 5%
- Instantaneous voltage reduction capacity: 165V ACContinues to run above. Continues to run when reduced to less than 165V AC 15ms
- Frequency number range: 0.5~ 250 Hz
- Frequency number indicates: Digital Display
- Frequency resolution: Digital setting : 100 Hz following : 0.1Hz digital setting : 100 Hz or more : 1 Hz
- Control mode: High carrier frequency sinusoidal PWM control (V / F control )
- Carrier frequency: There are nine kinds of choices may (0.8 ~ 15kHz variable ) (0.8,1.1,1.6,2.5,5.0,7.5,10.0,12.5,15.0kHz)
Voltage / frequency characteristic
- Base frequency : 50,60Hz fixed setting and 45 ~ 250Hz arbitrarily set V / F curve: constant torque , square torque mode ( select switch )
- Torque boost: 0Arbitrarily set to 40%

System Move:
- Regenerative braking torque: 80%The above
- DC braking: In the stop frequency following actions. Braking torque level : 0 to 100 ( 20 section setting )Braking time : 0.1 to 120 seconds arbitrarily set.
RUN, STOP: Operation panel switch?Control terminal of the input signal ( open command signal , closing command signal )?Communication command (RS485)
- Frequency setting signal: Operating panel settings?Door operation mode setting?Communication command (RS485)
- Door operation mode setting:
  1.Opening and closing frequency: The maximum speed can be set to 6
  2.Acceleration and deceleration time: opening and closing of each frequency setting.
  3.Door shift position : maximum set 5.Door remains Frequency: 1 speed ( opening and closing can be set separately )
  4.Door Holding Torque: Maintain the current settings ( shutter can be set separately )
- Gate control functions:
  Gate speed is controlled by coder
  Gate speed is controlled by SW ( switch ) mode
  Door amplitude measurement function
  Door sandwiched detection function

Control System:
- Acceleration and deceleration time: 0.04~ 999 seconds ( acceleration and deceleration set individually )
- Acceleration and deceleration characteristics: S -shaped linear feature ( select switch )
- Stop Mode: Deceleration stop , Coast stop ( select switch )
- Stop frequency: 0.5~ 60 Hz arbitrarily set
- Reset function: Stop signal is reset , panel reset , power reset
- Frequency hopping set: Can set maximum 3 ( frequency hopping amplitude arbitrarily set at 1 ~ 10 Hz)
- Upper limit frequency setting: 0.5~ 250 Hz arbitrarily set
- Lower frequency setting: 0.5~ 250 Hz arbitrarily set

Control terminal:
- Input signal:
  On/ off command signal: 1 a contact signal
  On/ off Arrival signal: 1 a or 1 b contact signal
  Safety sensor: 1 a or 1 b contact signal
  On/ off Transmission signal: 1 a or 1 b contact signal
  Gate position detection signal: decoder signal (2-phase input)
- Output signal:
  Relay output: 3 points, 1C contacts (contact capacity AC 230V, 0.3 A, 30 DC V, 0.3 A resistor load)
  Output function: operation signal, signal inversion, arrival signal, overload alarm, open arrival signal, closed at signal, the folder into the detection, abnormal alarm (optional)
- Communication function:
  Interface: RS485 serial communication interface
  Communication speed: 4800/9600/19200 bps (optional)
  Communication protocol:MEWTOCOL-COM
  Communication mode: half duplex mode
  The maximum connection: 31 units?
  Maximum transmission distance: 500 m
- Built-in power supply: DC 12V -10%/+20%  0.1A (below) for decoder power supply

Tripping operation:
Overcurrent and temperature anomalies (SC1 ~ 3), overcurrent (OC1 ~ 3), overloading, electronic thermal (OL), insufficient voltage (LU), over voltage (OU1), operating exception (OP), 5 (En1, 2).

Environment:
- Ambient temperature and humidity:-10~50 degree ceisuis 90% RH (25 DEG C, there should be no dew)
Transport, storage temperature and humidity: - 25 ~ 65 C below 95% RH (25 DEG C, there should be no dew)
- Vibration: 5.9 m/s G {0.6} 2
- Elevation: 1000 m below
- Medium: air, indoor should be no corrosive gas, flammable gas, oil mist and dust
- Protective structure: IP30 shielding
- Cooling method: self cooling

Package included:
- 1 x  Panasonic Inverter Panasonic Inverter 0.4kw door elevator parts AAD03011DK AAD0302

Write a review

Note: We will keep it confidential.
Note: HTML is not translated!
 