Specifications

Specifications
Maximum voltage between any terminal and earth ground
  600 V
Surge protection
  6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
  33 segments, updates 32 per second
Operating Temperature
  -10 °C to + 50 °C
Storage Temperature
  -40 °C to + 60 °C
Battery type
  9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
  400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5 % + 2
Diode Test
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 μF / 0.01 μF
Range/Resolution: 100.0 μF / 0.1 μF
Range/Resolution: 9999 μF / 1 μF
Range/Resolution: 100 μF to 1000 μF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 μF
Accuracy: 5% + 20%
LoZ capacitance
Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical
Temperature2 (Including Type-K thermocouple )
Range/Resolution: -40 °C to 400 °C / 0.1 °C
Accuracy: 1% + 102
Range/Resolution: -40 °F to 752 °C / 0.2 °F
Accuracy: 1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
DC μamps
Range/Resolution: 600.0 μA / 0.1 μA
Accuracy: 1.0% + 2
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2