• M8 Transistor Tester Upgrade M328 ESR Inductance Capacitance Multifunctional Meter Measurement for DIY

M8 Transistor Tester Upgrade M328 ESR Inductance Capacitance Multifunctional Meter Measurement for DIY

Availability: In stock, usually dispatched in 1 business day

  • Price:$22.82
  • Price in reward points: 228 Reward Points: 2
  • Quantity 3+ units 10+ units 30+ units 50+ units More
    Price /Unit $22.36 $21.91 $21.22 $20.31 Contact US
Quantity:

M8 Transistor Tester Upgrade M328 ESR Inductance Capacitance Multifunctional Meter Measurement for DIY
 
Features:

- One key measurement operation, the time delay automatically shut off power. Support battery operation.
- Automatic detectionPNPAndNPNBipolar transistor,N,PChannelMOSFET,JFETField effect transistor, diode, double diode, thyristor, resistance, capacitance, inductance. Automatic detection pin definition.
- Current amplification factor for measuring the bipolar transistor (B) and the conduction voltage of the emitter.Uf). Darlington transistor can be identified by high threshold voltage and high current amplification factor.
- Bipolar transistor can be detected andMOSFETThe internal protection diode is displayed on the screen.
- Measurement for MOSFET Threshold voltage and gate capacitance values.
- Support for the measurement of two resistance, potentiometer can also be measured. If the potentiometer is adjusted to its end, the tester can not distinguish between the middle and the two ends of the pin.
- Resolution of resistance measurement is 0.1Ohm, the maximum value of the measurement50MOhm.
- Capacitance measurement range25pfTo100mF(10000UF). Resolution of up to1 pF, inductance measurement range is0.01MH-20H, otherwise it will be shown as a resistor if the inductance of the DC resistance is higher than that of the2100Europe will also show resistance.
- Can detect2UFThe equivalent series resistance of the capacitorESRResolution is0.01Ohm. This function is very important for the detection of capacitance performance.
- Can display the correct direction of the symbol of the two diodes, while showing the forward voltage drop.
- LEDThe positive pressure drop is higher than the normal value of the diode. Double light emitting diode detector for double diode. Detection of light emitting diode will be shining.
- Each time the test is about two seconds, only a large capacitance and inductance measurement will take a long time.

Correction:
Short three test end,enter the test, the screen prompts correction step. When prompted to disconnect the short end of the calibration time off three tests will continue, when prompted in the 1-3 foot access 100nF capacitor over time, access to distribution after correction capacitors 1uF program will automatically enter the next step. Correction until the end of the restart to complete the correction.

Notes:
- The capacitance before teating must be discharged, otherwise it may damage the instrument!
- Can measure components: diodes, capacitors, resistors, transistors, SCR, MOS tube
-  The instrument is only used to measure electronic devices, can not test power devices (such as high-power MOS, thyristor, etc.)

Main parameters and use:
- ATmega328Micro controller
- 12864Graphics LCD test results.
- One key operation, automatic power off power.
- Automatic detectionPNPAndNPNBipolar transistor,N,PChannelMOSFET,JFET, diode, double diode, thyristor,Controllable silicon.
- Automatic detection pin layout.
- The current amplification factor and the threshold voltage of the emitter junction are measured.
- Darlington transistor can be identified by high threshold voltage and high current amplification factor.
- Bipolar transistor,MOSFETDetection of protective diode.
- MeasurementMOSFETThreshold voltage and gate capacitance values.
- Support for the measurement of two resistors and symbols, the top four digits and the unit display. The display of the resistance sign at both ends is connected to the tester probe number (1-3). So potentiometer can also be measured.
- Resolution of resistance measurement is 0.1, Highest measurement value50MOhm.
- A capacitor can be detected and measured. Top four digit and unit display. Values can be from25pf(8MHzClock50pF@ 1MHzClock) to100mF. Resolution of up to1 pF(@ 8MHzClock.
- Can be right2UFThe equivalent series resistance of the capacitorESRCapacitance measurement. Resolution0.01Ohm.
- Can be measured at the same time2A diode, and display correct pin layout and forward voltage drop.
- LEDThe forward voltage drop is much higher than normal. Double light emitting diode detector for double diode.
- Zener diode can be detected, if the reverse breakdown voltage is lower than the4.5V. Will be shown as two diodes.
- Only a single measurement is needed to find out the connection of the whole bridge.
- Could not detect lower than25pfCapacitor, but can be in parallel with a diode or greater than25pfCapacitor parallel. The measurement results can be subtracted from the parallel capacitor value.
- Resistance lower2100Ohm will measure the inductance, the range will be from0.01mH--20HBut the precision is not good.
- The test time is about two seconds,,Capacitance and inductance measurement can be extended with the increase of the value of the time.

Package Including:
- 1 x Tester(no battery)

Write a review

Note: We will keep it confidential.
Note: HTML is not translated!
 
Captcha