MS2600 3999 Open Jaw Clamp Meter Compared with Fluke


MS2600 is an open jaw digital electrical tester. There are DCV, ACV, ACA, Ω, CAP, frequency, diode test, continuity test and duty cycle test function. Moreover, there are auto and manual range, relative measurement, data hold, and backlight auto off time limit mode. Test leads can be REPLACEed on groove of back of the tester.

Specifications:
- Meets IEC1010-1 concerning safety requirements
- Display: 3999 counts
- DCV: 4/40/400V±0.7%, 1000V±0.8%
- ACV: 4/40/400V±0.8%, 700V±1.0%
- ACA: 200A±3.0% (50Hz to 400Hz)
- Resistance: 400/4k/40k/400k/4MΩ±1.2%, 40MΩ±2.0%
- CAP: 40n/400n/4µF±4.0%
- Frequency: 10Hz to 100kHz±2.0%
- Duty cycle: 0.1% to 99.9%
- Back light
- Power: Battery 6F22 (9V) x 1
- Size: 192mm x 68mm x 43mm
- Weight: Approx. 230g

DC Voltage

Range Resolution Accuracy
0- 4V 1mV +- 0.7% of reading +- 1 digit
4- 40V 10mV
40- 400V 0.1V
400- 1000V 1V +- 0.8 % of reading +- 3 digits

Input impedance : 10M Ohms

Overload protection:1000V DC or 700 AC RMS

AC Voltage

Range Resolution Accuracy
0- 4V 1mV +- 0.8 % of reading +- 5 digits
4- 40V 10mV
40- 400V 0.1V
400- 700V 1V +- 1.0 % of reading +- 10 digits
Input impedance: 10 M Ohms

Frequency Range : 40 Hz to 400 Hz

Overload protection:1000V DC or 700 AC RMS

AC current

Range Resolution Accuracy
0  -  200A 0.1A +-3.0 % of reading +- 3 digits
Overload protection: 240A for 60 seconds Max.

Frequency range: 50 Hz to 500 Hz

Resistance

Range Resolution Accuracy
0- 400 Ohm 0.1 Ohm +-1.2 % of reading +- 1digits
4K Ohm 1 Ohm
40K Ohm 10 Ohm
400K Ohm 0.1K Ohm
4M Ohm 1 K Ohm
40 M Ohm 10 K Ohm  
Overload protection: 250V DC or rms ac for all ranges.

Capacitance

Range Resolution Accuracy
0- 40 nF 10pF +- 4.0 % of reading +- 10 digits
400 nF 0.1nF
4uF 1nF
40uF 10nF  
Overload Protection: 250 V DC or rms. AC for all ranges.

Frequency Measurement

Range Resolution Accuracy
0- 40 Hz 0.01HZ +- 2.0 % of reading +- 1 digits
400 Hz 0.1Hz
40 KHz 1 Hz
100KHz 0.1KHz
Measurement range: 1V to 10V RMS, 10 Hz to 100KHz

Audible continuity and diode

Buzz If continuity exits ( less than 30 Ohm), built in buzz with sound
Diode Show approx forward voltage of the diode
Duty Cycle 0.1 % 99.9 %
Power off 30 minutes after , it shuts itself off when no operation.