Quantity | 3+ units | 10+ units | 30+ units | 50+ units | More |
---|---|---|---|---|---|
Price /Unit | $39.28 | $38.48 | $37.27 | $35.67 | Contact US |
Description:
- Load cell amplifier RW-GT01A can connect with all kinds of fullbridg
strain load cells to measure weight, force, tension etc.. It can adjust,
filter and amplify mv electrical signal and output 0-5V(10V) and 4-20mA
standard industrial control signal to support PLC or other measuring
control system acquisition. Internal active low pass filter can filter
out electromagnetic interference in industry site effectively. It takes
din rail enclosure to mount easily.
Specifications:
- Installation mode: standard din rail mounting
- Current Output Resistance: <500Ω
- Voltage Output Resistance:>5kΩ
- Signal Output: 0-10V
- Load Cell Excitation Current:<60mA
- Load Cell Excitation Voltage: 5Vdc±5%(normal Excitation voltage 5-12V load cell)
- Temperature Drift: better than 100ppm
- Accuracy: better than 0.1%F.S.
- Current Full Scale Adjustment Range:10%F.S.
- Current Zero Point Adjustment Range: 10%F.S.
- Voltage Full Scale Adjustment Range: 10%F.S.
- Voltage Zero Point Adjustment Range: precision tune 10%F.S. ; coarse tune 40% F.S.
- Load Cell Sensitivity Range: 2.0mV/V±10%
- Humidity: 85%RH, non condensation
- Storage Temperature Range: -20ºC to 80ºC
- Operation Temperature Range: -10ºC to 50ºC
- Dimension:115x37x58mm(LxWxL)
- Net Weight:100g
- Wiring Mode: screw-type wiring terminal
- Max Power:4W (supporting power supply for 350Ωload cell 4 pcs with current output 20mA)
- Power Supply: 24Vdc(18-27Vdc)
Size(mm)