STC-1000 Digital Temperature Controller Thermoregulator Thermostat Incubator for Heating Cooling 24V
Specification:
Power supply: DC 24V
Temperature range: -50℃~+110℃
Resolution: 0.1
Accuracy: ±1℃
Relay output contact capacity: heating: 10A/240V AC, cooling: 10A/240V CA
Sensor type h: imported NTC sensor, line length 1 meter
Shell material: gray ABS flame retardant plastic shell
Net weight: 120g
Gross: weight 140g
Long press Set for 5 seconds to enter internal parameter setting, press up and down to switch P0...P8, press Rst to confirm return.
P0 cooling, heating mode
High temperature start is cooling mode, please set to C.
Low temperature start is heating mode, please set to H.
P1 hysteresis setting
In heating mode (H): measured value ≤ set value-when output difference starts output heating to set value and stops.
In cooling mode (C): when the measured value ≥ set value + when output difference starts output cooling to set value and stops.
P2 maximum setting range: the highest value does not exceed this value when setting the temperature.
P3 minimum setting range: the minimum value is not lower than this value when setting the temperature.
P4 temperature correction
When there is a deviation between the measured temperature and the standard temperature, you can use this function to correct, the temperature after correction = the temperature before correction + the correction value.
P5 delay start time unit: minutes
When controlling the cooling of the compressor equipment, the delay time can be set according to the needs. When the controller outputs, the equipment will not start immediately, and it needs to start after running the set delay time.
P6 high temperature alarm
When the measured value is greater than this value, the screen displays --- and audible alarm, and the output is forced to be disconnected at the same time.
P7 data lock function
Open the data lock, you can keep the current settings unchanged, at this time the set temperature and function are invalid, if you need to modify, you need to close the data lock function.
P8 factory reset
Long press SET to switch to P8, press SET once to set to on, press Rst to restore the factory settings.
You can also press and hold the +- key to hold the power-on self-test and restore factory settings.
Instructions:
1. Please connect the power supply according to the parameters and circuit diagram, and connect the cooling or heating equipment to the output.
2. Enter the internal settings to select heating (enter P0 to select H) or cooling (enter P0 to select C) mode as required.
3. Method of setting temperature: Press Set once to flash, press up and down to set the desired temperature, press Rst to confirm and return.
4. OUT indicator on the panel: flashing means cooling or heating start delay, steady light means output.
5. Nixie tube: display LLL is the sensor open circuit; display HHH is beyond the measurement range, the thermostat will force power off; display --- for high temperature alarm.